4-20 DURADRIVE HDC01.1 Drive Controller DURADRIVE Drive Controllers
DOK-DURADR-HDC01.1****-PR02-EN-P
CE label, C-UL listing, Tests
CEf1.fh7
Fig. 4-25: CE label
Per UL508 C under file no. E134201.
ULf2.fh7
LISTED
INDUSTRIAL
CONTROL
EQUIPMENT
97Y4
Fig. 4-26: C-UL listing
High-voltage test according to
EN50178
Routine test with DC2100V 1s
Insulation test according to EN50178 Routine test with DC500 1s
Separation between the electrical
circuits of the control and high
voltage power
safe separation according to
EN50178
Clearances and creepage distances according to EN50178
Fig. 4-27: Tests