12.4 Cleaning the drive controller
DANGER
High electrical voltage!
Prior to cleaning switch off the drive controller.
Secure it against switching back on.
WARNING
Burns caused by hot parts with temperatures of
more than 30 °C!
Depending on the work load of the unit and the
ambient conditions, the housing and the power
heatsink can be very hot. Before starting to work at
the unit, allow it to cool down and measure the
temperature.
CAUTION
Danger of damages!
Do not use cleaning tools with sharp edges.
Do not use aggressive cleaning agents like alcohol.
Drive controllers with cooling fan unit only: Clean the cooling air inlet
using a brush or compressed air.
Drive controllers with cooling fan unit only: Dismount the cooling air
guide (see page 11-4).
Clean the heatsink and the air guides using a brush or compressed
air.
Drive controllers with cooling fan unit only: Remount the cooling air
guide (see page 11-4).
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rexroth Indramat DURADRIVE SYSTEM200 and is the answer not in the manual?

Rexroth Indramat DURADRIVE SYSTEM200 Specifications

General IconGeneral
BrandRexroth Indramat
ModelDURADRIVE SYSTEM200
CategoryController
LanguageEnglish

Related product manuals