EasyManuals Logo

REXROTH ECODRIVE03 User Manual

REXROTH ECODRIVE03
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
IV Contents ECODRIVE03-SGP-03VRS
DOK-ECODR3-SGP-03VRS**-WA01-EN-P
5 Description of Diagnostic Messages B…; C…, D… and A 5-1
5.1 Command Diagnostic Messages B…, C… and D…...................................................................... 5-1
B100 Command Release motor holding brake........................................................................ 5-2
B101 Command not enabled ................................................................................................... 5-2
B200 Brake check command................................................................................................... 5-2
B201 Brake check only with drive enable ................................................................................ 5-2
B202 Error during abrasion of the brake.................................................................................. 5-2
B203 Brake torque too low.......................................................................................................5-3
C100 Communication phase 3 transition check ...................................................................... 5-3
C101 Invalid communication parameter (S-0-0021)................................................................ 5-3
C102 Limit error communication parameter (S-0-0021) .......................................................... 5-3
C104 Config. IDN for MDT not configurable ............................................................................ 5-4
C105 Configurated length > max. length for MDT................................................................... 5-4
C106 Config. IDN for AT not configurable ............................................................................... 5-4
C107 Configurated length > max. length for AT ...................................................................... 5-5
C108 Time slot parameter > Sercos cycle time....................................................................... 5-5
C109 Position of data record in MDT (S-0-0009) even ...........................................................5-5
C110 Length of MDT (S-0-0010) odd ...................................................................................... 5-6
C111 ID9 + Record length - 1 > length MDT (S-0-0010)......................................................... 5-6
C112 TNcyc (S-0-0001) or TScyc (S-0-0002) error................................................................. 5-6
C113 Relation TNcyc (S-0-0001) to TScyc (S-0-0002) error................................................... 5-7
C114 T4 > TScyc (S-0-0002) - T4min (S-0-0005) ................................................................... 5-7
C115 T2 too small....................................................................................................................5-7
C118 Order of MDT configuration wrong................................................................................. 5-7
C200 Communication phase 4 transition check ...................................................................... 5-8
C201 Invalid parameter(s) (->S-0-0022).................................................................................. 5-8
C202 Parameter limit error (->S-0-0022)................................................................................. 5-8
C203 Parameter calculation error (->S-0-0022) ...................................................................... 5-9
C204 Motor type P-0-4014 incorrect........................................................................................ 5-9
C210 Feedback 2 required (->S-0-0022)................................................................................. 5-9
C211 Invalid feedback data (->S-0-0022).............................................................................. 5-10
C212 Invalid amplifier data (->S-0-0022)............................................................................... 5-10
C213 Position data scaling error............................................................................................ 5-10
C214 Velocity data scaling error............................................................................................ 5-11
C215 Acceleration data scaling error..................................................................................... 5-11
C216 Torque/force data scaling error .................................................................................... 5-12
C217 Feedback1 data reading error...................................................................................... 5-12
C218 Feedback 2 data reading error..................................................................................... 5-13
C220 Feedback 1 initializing error ......................................................................................... 5-13
C221 Feedback 2 initializing error ......................................................................................... 5-14
C223 Input value for max. range too high.............................................................................. 5-14
C227 Modulo range error....................................................................................................... 5-14
C228 Controller type S-0-0140 wrong ................................................................................... 5-15
C234 Encoder combination not possible ............................................................................... 5-15
C235 Load-side motor encoder with inductance motor only ................................................. 5-15