SERVICE PROGRAM 9 March 2004
5-36
5802
Machine Free Run
5802 1
Conducts machine free run (including the scanner unit). Press “ON” to start; press
“OFF” to stop.
Input Check
5803
☛
5.1.6
Output Check 5804
☛
5.1.7
5807* Area Selection
5807 1 Selects the display language group.
2 North America 3 Europe 5 Asia 6 China
SP5-807-001 is not cleared by SP5-801-001 and SP5-998-001 (☛ 5.1.5).
5811*
Serial Num Input
5811 1
☛
5.1.8
5812*
Service TEL
Telephone 5812 1
Specifies the telephone number of the service representative. (The number is
displayed when a service call condition occurs.) To input a dash, press #. To
delete the current telephone number, press &.
Facsimile 5812 2
Specifies the fax number printed on user counter reports. To input a dash, press
#. To delete the current fax number, press &.
5816*
Remote Service
I/F Setting
[0=Remote diagnostics off/1=Serial (CSS or NRS)
remote diagnostics on/2=Network remote diagnostics]
5816 1
Enables or disables the remote diagnostics function.
CE Call 5816 2
Allows the customer representative to start or end the remote machine check using
CSS or NRS by pressing the center report key.
Function Flag [
0
= Disabled / 1 = Enabled] 5816 3
Enables or disables remote diagnosis via the NRS network.
Device Information Call Display [
0
= Disabled / 1 = Enabled] 5816 6
Determines whether the device information call (NRS) is displayed.
SSL Disable [
0
= Disabled / 1 = Enabled] 5816 7
Determines whether the SSL sends the remote-communication-gate confirmation.
RCG Connect Timeout
[1∼ 90 / 10 / 1 second/step]
5816 8
Sets the timer for the remote-communication-gate connection (NRS).
RCG Write to Timeout
[0∼ 100 /
60
/ 1 second/step]
5816 9
Sets the timer for writing data to the remote communication gate (NRS).
RCG Read Timeout
[0
∼
100 /
60
/ 1 second/step]
5816 10
Sets the timer for reading data from the remote communication gate (NRS).