SM 4-31 G147
Trouble
-shooting
Printer setting error
954 D
The IPU does not respond with the settings
that are required to start image processing by
the printer.
Software defective
Memory setting error
955 D
The IPU does not respond with the settings
that are required to start image processing
using the memory.
Software defective
980 D NVRAM Error
A critical SP code setting is not
within range. If the machine is
allowed to operate in this condition,
this could lead to toner overflow and
damage the machine.
See description below this table.
SP Code Acceptable
Range
SP Code
SP2005 004 Charge Roller
Adjustment 2
-1000 to -2000 V SP2005 004 Charge
Roller Adjustment 2
SP2802 001 TD Sensor Manual
Setting VTS
1.00 to 5.00 V SP2802 001 TD
Sensor Manual
Setting VTS
SP2802 002 TD Sensor Manual
Setting VTMAX
1.00 to 5.00 V SP2802 002 TD
Sensor Manual
Setting VTMAX
SP2802 003 TD Sensor Manual
Setting VTMIN
1.00 to 5.00 V SP2802 003 TD
Sensor Manual
Setting VTMIN