G147 5-14 SM
SP2-109-4 to adjust the laser beam pitch.
400dpi Init Set 400 dpi Initial Setting
003
Initializes the laser beam pitch for 400 dpi using the value for SP2-109-1.
After entering a value for SP2-109-1, this SP must be used.
600dpi Init Set 600 dpi Initial Setting
004
Initializes the laser beam pitch for 600 dpi using the value for SP2-109-2.
After entering a value for SP2-109-2, this SP must be used.
Auto Int Set Auto Pitch Adjustment Interval
005
[50 ~ 65535 / 1000 / 1 step]
Sets the interval for automatic laser beam pitch adjustment.
When the number of times that the resolution has been changed reaches this
value, the laser unit position is automatically corrected.
LD Unit Position Current LD Unit Position
006
Displays the current LD unit position (number of pulses from home position). If
this is different from the value of 2-109-1 or 2-109-2, LD unit positioning has
failed.
Pitch Change Cnt Beam Pitch Change Counter
007
Displays how many times the LD unit position has been changed (how many
times the resolution has changed.)
When the laser beam pitch adjustment is done, this counter is reset to zero.
Pitch Data Reset Beam Pitch Data Reset
008
Resets the values of SP2-109-6 and SP2-109-7.
After replacing the LD unit, this SP mode must be performed. See the LD Unit
Removal Procedure.
Test Mode dpi DFU
2110
[See below / 8/ 0 ~ 18]
Sets the resolution (dpi).