SM 5-15 G147
Service
Tables
Any setting other than 0, 4, or 8 will cause an error.
0 = 400 x 400 dpi
4= 300 x 300 dpi
8= 600 x 600 dpi
Polyg MO Off T. Polygon Motor Off Timer
2112
[0 ~ 60 s / 10 s / 5 s step]
Input the time that the polygon motor is to switch off after the printer has remained
idle for the specified time and entered the standby mode.
If set to zero, the polygon motor never switches off in standby mode. However, if
the machine enters the energy saver mode, the polygon motor will ignore the zero
setting and switch itself off.
2201 Developer Bias Development Bias Adjustment
Image Dev Bias [-200 ~ -700 / -540 V / 10V step]
001
Adjusts the development bias for copying.
Use as a temporary measure to correct faint copies from an aging drum.
ID Sensor Pattern [- 200 ~ -700 / -380V / 10V step]
002
Adjusts the development bias for the ID sensor pattern for VSP
Force Toner Supp Forced Toner Supply
2207
Forces the toner bottle to supply toner at 1-second intervals for up to 30 seconds.
To start, press [#Enter].
Toner Supp Mode Toner Supply Mode
2208
[0: Sensor control, 1: Image pixel count
Selects the toner mode.
If you select 1, SP2-209-002 should be set to its default value. Use image pixel