SM 5-33 G147
Service
Tables
0: Alarm off
1~9999: Alarm goes off when Value (1~9999) ≥ PM counter
003 PCU Count
This SP sets the timing of the display warning for
replacement of the PCU. When printing reaches this total,
the replace PCU warning is issued.
[0 ~ 150 / 150 / 1 step] 0: No alarm is issued
For example, when the number of prints reaches 150,000
with the default setting of "150" in effect, (150 x 1,000) the
warning is issued with the PM Counter Display (SP7803)
after the number of prints exceeds 150,000.
Jam Alarm Japan Only
5504
Sets the alarm to sound for the specified jam level (document misfeeds are not
included).
[0~3 / 3 / 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
Error Alarm
5505
Sets the error alarm level. Japan only DFU
[0~255 / 50 / 100 copies per step]
5507 Supply Alarm
001 Paper Supply Ala(rm)
0:Off 1:On
Switches the control call on/off for the paper supply.
DFU
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified number
transfer sheets for each paper size (A3, A4, B4, B5,