SC No. Level Error Name/Error Condition/Major Cause/Solution
SC561-00 A Pressurized Central Thermistor Disconnection
Below 0 degree C (or below 3F9) detected for (t12) seconds
continuously.
Detection period 100ms, detection count: 10 times or more.
Thermistor disconnection
Connector disconnected
Replace the thermistor
Reset the connector
Replace the connector
Replace the fusing unit
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC562-02 A Pressurized Central Thermistor Does Not Reload
Does not reach (T21) degree C after heater 1ON for (t3) seconds.
Thermistor dirt
Thermistor deformation, float
Outside input voltage guarantee
After excess temperature rise prevention unit operation
Replace the thermistor
Make sure that the input voltage is within acceptable limits
Replace the fusing unit