SC No. Level Error Name/Error Condition/Major Cause/Solution
SC561-00 A Pressurized Central Thermistor Disconnection
Below 0 degree C (or below 3F9) detected for (t12) seconds
continuously.
Detection period 100ms, detection count: 10 times or more.
• Thermistor disconnection
• Connector disconnected
• Replace the thermistor
• Reset the connector
• Replace the connector
• Replace the fusing unit
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC562-02 A Pressurized Central Thermistor Does Not Reload
Does not reach (T21) degree C after heater 1ON for (t3) seconds.
• Thermistor dirt
• Thermistor deformation, float
• Outside input voltage guarantee
• After excess temperature rise prevention unit operation
• Replace the thermistor
• Make sure that the input voltage is within acceptable limits
• Replace the fusing unit
Service Call 501-584