SC No. Level Error Name/Error Condition/Major Cause/Solution
SC563-00 A Pressurized Central Thermistor High Temperature Detection (software)
Above (T3) degrees C detected for (t4) seconds continuously.
Detection period: 100ms, detection count: 10 times or more.
Triac short-circuit
IOB defective
BCU defective
Replace the IOB
Replace the BCU
Replace the fusing unit
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC564-00 A Pressurized Central Thermistor High Temperature Detection (hardware)
Above (T4) degrees C detected
Triac short-circuit
IOB controller defective
BCU controller defective
Fusing control: out of control
Replace the IOB
Replace the BCU
Replace the fusing unit
5. Troubleshooting