01/2022
Page 69
5IN2933
Defining Automatically-Operated UOs and Arming
Operations
The Grand Master can configure the following automated system operations according to
schedules and other criteria that the Grand Master defines:
One-time system arming/disarming: (For arming within the next 24 hours
Re-occurring weekly schedules: Up to 64, for arming/disarming the system and/or
activating/deactivating up to 4 UOs
Vacation schedules: Up to 99, for UO activation and system arming
NOTE: When defining schedules for automatically-operated UOs or arming operations, you
may find it handy to use the scheduling chart for listing the details (see Appendix A:
Scheduling Chart for Automatic UO & Arming Operations, page 83).
Defining a "One-Time" Schedule for Automatic Arming
To define a "one-time" system arming/disarming:
1. At the keypad, enter your Grand Master code, and then press OK.
2. Scroll to Clock and then press OK.
3. Scroll to Scheduler and then press OK.
4. Scroll to One Time and then press OK.
5. Scroll to Next Arm and then press OK.
6. Select the partitions to arm. As the partitions are grouped in blocks of 10, scroll to the
relevant block and then select the partition(s) by entering the respective partition
numbers.
7. Press OK, and then enter the time for the arming to occur (within the next 24 hours); the
keypad sounds a confirmation beep.
8. Scroll to Next Disarm and then press OK.
9. Select the partitions to disarm. As the partitions are grouped in blocks of 10, scroll to the
relevant block and then select the partitions by entering the respective partition numbers.
10. Press OK.
11. You can now enter a disarming time; the keypad sounds a confirmation beep.

Table of Contents