Configuring the Arm/Disarm Option
Selecting an Arming Mode for the Arming/Disarming Schedule
1. Scroll to 3)ARMING MODE, and then press OK.
2. Scroll to an arming mode: ARM (full arming), STAY (partial arming), or GROUP
(group arming), and then press OK.
3. [For Group mode]: Select the group letter(s) to automatically arm
(each selected group displays as Y). To undo a selection, press the respective group
letter again. Now press OK.
4. [For all three modes]: Select the day/time (required) and define a label for an
arming/disarming schedule (optional) – see the following procedures:
Setting the Day & Time for the Arming/Disarming Schedule
1. Scroll to 4)DAY/TIME, and then press OK.
2. Scroll to a day to assign ARM and DISARM time periods – or scroll to 8)ALL
to assign those time periods to all days of the week, then press OK.
NOTE: If you don't want to schedule time periods for any day(s), make sure the
respective ARM/DISARM times are set to the defaults (00:00).
3. Enter the ARM time for the 1st time period, and then press OK.
4. Enter the DISARM time for the 1st time period, and then press OK.
5. Repeat the prior two steps for the 2nd time period if applicable.
6. Set ARM/DISARM time periods for other days of the week as needed.
Defining a Label for the Arming/Disarming Schedule
1. Scroll to 5)LABEL, and then press OK.
2. Enter a label (see Creating or Editing Labels, page 19), and then press OK.
Turning the Inactivity Timer On or Off for the Arming/Disarming Schedule
If there is no detection from any of the zones in partitions with an automatic schedule
(that has the Arm/Disarm option defined by the Grand Master with the Inactivity
Timer set to ON), then those partitions will be automatically armed according to the
(installer-set) Inactivity Timer parameter definition.
1. Scroll to 6)INACTIVE, and then press OK.
2. Toggle to ON (to turn the Inactivity Timer on) or OFF (to turn it off), and then press
OK.