1. OUTLINE
IMR02C15-E4 1-5
1.4 Model Code
Check that the product received is correctly specified by referring to the following model code list:
If the product is not identical to the specifications, please contact RKC sales office or the agent.
Suffix code
□
□□□-□□-□*□□-□□/□□/Y
(1) (2) (3) (4) (5) (6) (7) (8) (9) (
10
)(
11
) (
12
)
Suffix code
Specifications
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12)
PID control with AT (Reverse action) F
PID control with AT (Direct action) D
Heat/Cool PID control with AT G
Heat/Cool PID control with AT
(for Extruder [air cooling])
A
Control Method
Heat/Cool PID control with AT
(for Extruder [water cooling]))
W
Measured input and Range Refer to Input Range Code Table.
Relay contact output M
Voltage pulse output V
Voltage output (0 to 5 V DC) 4
Voltage output (0 to 10 V DC) 5
Voltage output (1 to 5 V DC) 6
Current output (0 to 20 mA DC) 7
Current output (4 to 20 mA DC) 8
Triac output T
Output 1 (OUT1)
[Control output]
Open collector output
D
Output 2 (OUT2) None N
[Cool output or
transmission output]
1, 2
Refer to Output 2 Code Table.
24 V AC/DC 3
Power supply voltage
100 to 240 V AC
4
None N
1 point (DO1) 1
2 points (DO1, DO2) 2
Digital output
(DO1 to DO4)
3
4 points (DO1 to DO4) *
* Available for RB400/500/700/900 only 4
None N
CTL-6-P-N (for 0 to 30 A) 1 point *
P
CTL-12-S56-10L-N (for 0 to 100 A) 1 point * S
CTL-6-P-N (for 0 to 30 A) 2 points * T
Current transformer (CT)
input
CTL-12-S56-10L-N (for 0 to 100 A) 2 points *
* CT input is not available when code
"N" is specified for Digital output.
U
None N
RS-485 (RKC communication) 5
RS-485 (Modbus) 6
Digital input (2 points) A
RS-485 (RKC communication)
+ Digital input (2 points) *
* Available for RB400/500/700/900 only B
Communication function/
Digital input (DI)
RS-485 (Modbus) + Digital input (2 points) * * Available for RB400/500/700/900 only C
None N
Waterproof/Dustproof
Waterproof/Dustproof (NEMA 4X, IP66)
1
White N
Case color
Black A
None (No need to specify initial setting code) N
Quick start code
Specify quick start code (Refer to ■Quick start code)
1
Instrument version Version symbol Y
1
Transmission output can be specified as output 2 (OUT2), when Control Method is “F” (reverse action) or “D” (direct action).
2
For RB100, Output 2 (OUT2) can be specified as event output 3, when Control Method is “F”(reverse action) or “D” (direct action) and two digital outputs (DO1 and DO2) are
specified.
3
For RB400/500/700/900, the maximum number of digital outputs (DO) depends on output types of OUT1 and OUT2. Refer to the table of the maximum number of DO below.
Table of the maximum number of DO:
OUT2 (Including transmission output)
No OUT2 output M, V, D V (10 mA) V (20 mA) Current output Voltage output
M (Relay contact output), V (Voltage pulse output),
D (Open collector output)
4 4 4 4 4 4
V (Voltage pulse output) [Load: 10 mA] 4 4 4 4 2 ** 2 **
V (Voltage pulse output) [Load: 20 mA] 4 4 4 2 ** 2 ** 2 **
Current output 4 4 2 ** 2 ** 2 ** 2 **
OUT1 *
Voltage output 4 4 2 ** 2 ** 2 ** 2 **
* When the instrument has two digital outputs (DO1 and DO2) and no OUT2 output, “V” type output (load: 40 mA) can be specified for OUT1.
** Digital outputs DO3 and DO4 cannot be specified.
RB100
RB400
RB500
RB700
RB900