Command Reference - Base Software
R&S
®
CMW500
281User Manual 1173.9463.02 ─ 06
SYSTem:TZONe <Hour>, <Minute>
Specifies the offset of the local time to the Universal Time Coordinated (UTC) due to the
time zone. There may be an additional offset due to Daylight Saving Time (DST).
Changing the time zone (offset) does neither affect an eventual DST offset nor the time
zone configured via SYSTem:TIME:DSTime:RULE.
The local time is calculated as: local time = UTC + time zone offset + DST offset
Parameters:
<Hour> Range: -12 to 15
<Minute> Range: -59 to 59
Example:
SYSTem:TZONe?
Query the time zone information. Possible response: -3, -30
Meaning: local time = UTC - 3 hours - 30 minutes + DST offset
Firmware/Software: V3.0.12
6.3.15
Miscellaneous Instrument Settings
SYSTem:CONNector:TRANslation?.................................................................................281
FORMat:BASE[:DATA]...................................................................................................282
SYSTem:BASE:RELiability?............................................................................................282
SYSTem:GENerator:ALL:OFF.........................................................................................282
SYSTem:MEASurement:ALL:OFF...................................................................................282
SYSTem:SIGNaling:ALL:OFF..........................................................................................282
SYSTem:DISPlay:UPDate..............................................................................................283
SYSTem:KLOCk............................................................................................................283
SYSTem:VERSion?.......................................................................................................283
SYSTem:CONNector:TRANslation? <Connector>
Queries the relation between absolute and virtual connector names. You can query this
relation for either an absolute or a virtual name. As a result both absolute and virtual name
are returned. For background information see chapter 5.4.5.2, "RF Connector Values",
on page 155.
Query parameters:
<Connector> RF1O | RF1C | RF2C | RF3O | RF3C | RF4C | RFAO | RFAC |
RFBC
RF1C, RF2C, RF3C, RF4C, RF1O, RF3O:
RF 1 COM to RF 4 COM and RF 1/3 OUT front panel connectors
RFAC, RFBC, RFAO:
Virtual names for the RF COM and RF OUT connectors
Return values:
<VirtualConnector> RFAO | RFAC | RFBC
<AbsoluteConnector> RF1O | RF1C | RF2C | RF3O | RF3C | RF4C
Instrument-Control Commands