R&S PR100 User Manual
Result:
0...1023
Example:
MEMory:SAVE:AUTO:STOP? -> 180
MEMory
. :SAVE
. . :DIRect
. . . :STARt <mem_loc>
Sets first memory location that is used to save receiver settings when the
direct save button is pressed. The last location is set with
MEM:SAVE:DIR:STOP. A start location that is larger than the stop location is
rejected with error -221(“Settings conflict”). When the direct save button is
pressed, the receiver settings are saved into the first free direct-save memory-
location.
Parameters:
<mem_loc> 0...1023
Example:
MEMory:SAVE:DIRect:STARt 60
MEMory
. :SAVE
. . :DIRect
. . . :STARt?
Query of first memory location for direct save
Parameter:
none
Result:
0...1023
Example:
MEMory:SAVE:DIRect:STARt? -> 60