R&S PR100 User Manual
SYSTem
. :PRESet
. . :MEASurements
Reset only measurement related settings of the device.
Parameters:
None
Example:
SYSTem:PRESet:MEASurements
SYSTem
. :SECurity
. . :OPTion <code>
A special optional firmware can be activated by entering a certain option code.
The unit must be switched on anew to activate this optional software. For a list
of possible options, see the common command “*OPT?”.
Remark:
The SCPI interface itself is also an option. If this option is not active, none of
the commands in this interface work. However, this command is an exception.
When the SCPI option is not active, this command can be used to activate it.
Note that no error reports can be retrieved via “SYST:ERR?”, and none of the
other options can be activated as long as the SCPI option is not active.
Parameters:
<code> 8-digit number
Error codes:
-220 Parameter error incase optionkey is incorrect.
*RST state:
The options are maintained after a reset.
Example:
SYSTem:SECurity:OPTion "12345678"