EasyManua.ls Logo

Satel INTEGRA Plus - Page 49

Satel INTEGRA Plus
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SATEL INTEGRA Plus 47
Time to re-arm the parameter applies to the BANK VAULT partition type. After disarming, the
control panel will be analyzing for a defined period of time whether a door in the partition
will be opened by means of an access control module (partition keypad, code lock, etc.). If
the door is not opened, the partition will be automatically re-armed (the partition exit delay
countdown will not be running). If the time value is equal to 0, the partition will not be re-
armed. Irrespective of the preset value, if the DISARM DELAY parameter is 0, the partition
will not be re-armed.
Options
Arm by two codes [2 cds to arm] if this option is enabled, arming requires that codes be
entered in turn by two users.
Disarm by two codes [2 cds to d-arm] if this option is enabled, disarming requires that
codes be entered in turn by two users.
Codes on two keypads [Codes on 2 kpd] if this option is enabled and the partition is
armed/disarmed using two codes, they must be entered from different keypads.
Valid within 30 sec [1st code 30s] if this option is enabled and two codes are required for
arming/disarming, the second user has to enter the code within 30 seconds of entering the
code by the first user.
Timer priorityif this option is enabled, arming/disarming is always done by the timer. If this
option is disabled, the timer will disarm the partition if it was armed by the timer (if it was
armed by the user, the timer will not disarm the partition).
Infinite exit delay [Infin.ex.delay] if this option is enabled, the partition will be armed after
entering the code and then:
violating the 86. ENTRY/EXIT FINAL, 87. EXIT FINAL or 89. FINISHING EXIT DELAY type
zone,
shortening of the exit delay time by the user (see EXIT DELAY CLEARING option).
If partition is not armed within 260 seconds, the Arming failedevent will be registered to
the control panel memory. With the option enabled, the PARTITION EXIT DELAY will be taken
into account, if the partition is armed using a zone or timer.
Exit delay clearing [Fin.exit delay] if this option is enabled, you can reduce the exit delay
countdown by entering 9 from the keypad/partition keypad. The partition will be armed
immediately. The exit delay clearing is only available from the same keypad/partition
keypad, from which the partition was armed (the EXIT DELAY CLEARING ENABLE option must
be enabled in the keypad).
Default block time the option applies to the WITH TEMPORARY BLOCKING partition type. If the
option is enabled and the DEFAULT PART. BLOCK TIME is preset, the partition will be blocked
on arming for a default time period, as defined by the installer (the blocking time cannot be
programmed by the user).
Alarm disarm allowed the option applies to the WITH TEMPORARY BLOCK partition type.
During alarm, the partition can be disarmed by the users who do not have the ACCESS TO
TEMPORARY BLOCKED PARTITIONS
right.
Audible alarm after verification [Bell on 2nd] if this option is enabled, the alarms from
zones with the PRE-ALARM or WITH VERIFICATION option enabled will only trigger loud alarm
signaling after verification. The unverified alarms will not trigger loud alarm signaling.
Partition timer
Partitions can be controlled with an additional timer, which can be programmed:
in the keypad, using the function available in the user menu ([code] OPTIONS
PROGRAMMING
PARTITION TIMERS),

Table of Contents