70 Programming SATEL
6.2 Printer options
Printing the option enables on-line events printout by the printer connected to the RS-232
port of control panel mainboard.
6.2.1 Printout options
Include reporting status [Monitor.status] on the printout will appear the information if the
particular event was sent to the monitoring station (printout of the event information will
take place not immediately but after transmission to the station has been completed).
Print names/descriptions [Names/descript] determines if, besides the numbers of zones,
outputs, modules and users, also their names and descriptions are to be printed.
Wide paperprintout width will be 132 columns (if the option is disabled: 80 columns).
2400 bps (off:1200 bps) data will be sent to RS-232 port at a rate of 2400 bps (if the
option is disabled - at a rate of 1200 bps).
CR+LF (off: CR) parameter determining the control mode of paper feed in the printer.
Use parity bit the parity check of data transferred from the control panel to the printer is
enabled.
Parity EVEN (off: ODD) option determines the mode of parity check of data transferred
from the control panel to the printer. The option is relevant only if the USE PARITY BIT option
is active.
The other parameters of RS-232 transmission are permanently programmed (8 data
bits, 1 stop bit).
All the parameters regarding transmission through RS-232 (i.e. transmission rate,
CR+LF, parity, data bits and stop bits) are to be set identically on the control panel and
on the connected printer. Otherwise the printer will not operate at all, or the printout
will be illegible.
6.2.2 Printout contents
The options define what kind of information will be contained in the printout.
6.3 Other options
Permitted simple access codes [Simple codes] with this option enabled, with this
option enabled, it is possible to use codes containing less than three different digits (e.g.
1111 or 1212) or consisting of consecutive digits (e.g. 3456).
Notify of necessity to change access code [Notify of code] with this option enabled, the
keypad will notify the user of the necessity to change access code, if it is known to other
users.
Confirm commands with “1” [Confirm with 1] if this option is enabled, the LCD keypad
will require, in case of some functions, additional confirmation with the key 1.
Clear messaging on alarm clearing [Autoabort msg.] with this option enabled, clearing
the alarm can automatically cancel messaging about this alarm, if the user clearing the
alarm has the TELEPHONE MESSAGING CANCELING right.
Return to menu from Service Mode [SM -> menu] if this option is enabled, exiting the
service mode will be followed by return to the user menu instead of to the basic operating
mode of the keypad.
Return to menu from menu Test [Tests -> menu] if this option is enabled, exiting the
user function available in the TESTS or CHANGE OPTIONS submenu will be followed by return
to the submenu instead of to the basic operating mode of the keypad.
Fast module bus communication [Fast exp. bus] it is recommended to enable this option
to speed up communication with the modules. The option should only be disabled in case