SATEL INTEGRA Plus 69
based on descriptions from the control panel event log. ETHM-1 Plus or INT-GSM module
must be connected to the control panel.
Answering - modem [Modem answer.] with this option enabled, external initiation of the
communication between modem and control panel is possible.
Answering - audio [Voice answer.] with this option enabled, the control panel will carry out
the function of call answering.
The ANSWERING - AUDIO option must be enabled, if the users are to operate the alarm
system using the interactive voice menu offered by the INT-VG module.
Remote control with this option enabled, the control panel allows the users having
a telephone code to operate the REMOTE SWITCH outputs by using a phone. The option is
available if the ANSWERING AUDIO is enabled.
External modem [External modem] with this option enabled, the control panel will support
an external modem connected to the control panel RS-232 port.
Modem ISDN/GSM/ETHM [ISDN/GSM modem] enable this option if the ETHM-1 Plus /
ETHM-1 / INT-GSM / GSM / ISDN module is connected to the control panel RS-232 port.
The option is available if the EXTERNAL MODEM option has been enabled.
Answering - ETHM/GSM [Ext.mod.answ.] if this option is enabled, it is possible to
establish connection with the alarm control panel via the ETHM-1 / ETHM-1 Plus module,
INT-GSM module, GSM or ISDN modem. The option is available, if the EXTERNAL MODEM
and MODEM ISDN/GSM/ETHM options are enabled. The option is not available when the
ANSWERING - MODEM option is enabled, which also enables to establish connection with the
alarm control panel via the ETHM-1 / ETHM-1 Plus module, INT-GSM module, GSM or
ISDN modem.
Tone dialing with this option enabled, the control panel will tone dial the telephone
numbers (pulse dial, if this option is disabled).
Ground Start with this option enabled, the control panel will use the Ground Start method
to obtain signal on the telephone line (by grounding temporarily the telephone line wires).
Enable this option, if required by your phone service provider.
No dial tone test [No dialton.tst] with this option enabled, the control panel will not perform
the test for dial tone before dialing the number and will start dialing the number 5 seconds
after going off hook. This makes it possible for the control panel to dial the number when
some non-standard tones occur after going off hook (e.g. interrupted tone). When this
option is disabled, the control panel will start dialing the number 3 seconds after going off
hook, provided that the dial tone is present.
No answer test with this option enabled, in case of notifying by means of voice
messages, the control panel will not perform the test for off hook condition. The
voice message will be played back 15 seconds after completion of the number dialing.
Double voice message [Dbl. voice msg.] with this option enabled, the voice message is
played back twice during telephone messaging.
Double call with this option enabled, the control panel must be called twice for the modem
communication to be established. The first time you must wait for the preprogrammed
number of rings and hang up. Then you must call back within three minutes and the
control panel will answer the call immediately. This solution makes it possible to connect
after the control panel some additional devices which will be activated after a preset
number of rings (e.g. answering machine, fax, etc.).
Pulse dialing 1/1.5 (off 1/2) this option applies to dialing the telephone numbers by using
the pulse mode. Before you enable it, make yourself familiar with the valid standard of
pulse dialing.
Rings before answer [Rings to answer] number of rings after which the control panel will
go off hook.