SATEL INTEGRA Plus 91
3. Program the following for the monitoring station to which event codes are to be sent:
– reporting format in which the codes will be sent,
– server address (this address will not be used, but entering some character is required),
– identifiers with which the events will be sent,
– event assignment (if STATION 1 AND 2 is selected),
4. If a reporting format other than CONTACT ID (FULL) or SIA (FULL) is selected:
– assign identifiers to the partitions, zones, keypads and expansion modules,
– program the codes for events which are to be reported.
5. Define the parameters of test transmissions.
6. In the settings of the INT-GSM module (INT-GSM module connected to the control panel)
or ETHM-1 Plus module (INT-GSM module connected to the ETHM-1 Plus module):
– specify the priority of the SMS reporting,
– program the telephone number to which the SMS messages will be sent,
– configure the SMS message format.
11. Messaging
The control panel can inform the users about the system events by means of:
• voice messages. You must connect to the control panel:
– the INT-VG module or another voice synthesizer,
– telephone line or SATEL GSM module.
• voice messages (the INT-VG module or another voice synthesizer must be connected),
• PAGER type text messages, whose content can be programmed (the SATEL GSM
modules enable the PAGER messages to be converted into SMS). Connection of
telephone line or SATEL GSM module to the control panel is required.
• SMS messages, whose content is created automatically, based on descriptions from the
control panel event log memory. The INT-GSM module must be installed in the system or
the SATEL GSM module must be connected to the control panel (RS-232 ports of control
panel and module must be connected).
The required SATEL GSM module:
− GSM-X,
− module with LEON telephone and firmware version:
GSM LT-1: 1.14 or newer,
GSM LT-2: 2.14 or newer,
GSM-4: 4.14 or newer,
GSM-5: 5.14 or newer.
• e-mail messages, whose content is created automatically, based on descriptions from the
control panel event log memory. The ETHM-1 Plus or INT-GSM module is required to be
connected to the control panel.
Messaging is performed independently from reporting but reporting has the priority. If in the
course of messaging some events occur which must be reported to the monitoring station by
the control panel, the messaging will be interrupted. The control panel will resume the
messaging function after the event codes are reported to the monitoring station.