96 Programming SATEL
12.1.1 Users and remote switches
The telephone control function requires that REMOTE SWITCH type outputs, which can be
controlled by users, be individually assigned to each user.
12.2 Activation of the phone calls answering
1. Enable the ANSWERING - AUDIO option.
2. Define the rules of call answering by the control panel (RINGS BEFORE ANSWER parameter
and DOUBLE CALL option).
3. Define whether the function is to be available at all times, or only when selected partitions
are armed (function ANSWER IF PARTITIONS ARE ARMED).
4. Program the telephone codes for the users who are to use the function (see: USER
MANUAL).
12.3 Activation of the remote control
1. Activate the call answering function.
2. Enable the REMOTE CONTROL option.
3. Program the selected outputs as the REMOTE SWITCH.
4. Assign the REMOTE SWITCH type outputs to the users who are to use the function.
13. Control panel firmware update
Available on the www.satel.eu website is the current version of control panel firmware and
the FLASHX program enabling to write it to the control panel. In order to update the firmware:
1. Connect the control panel RS-232 or USB port to the computer port (for the connection
method please refer to the INSTALLER MANUAL).
2. Start the FLASHX program.
3. Click on the button to select the file with control panel new firmware.
4. Click on the button to indicate the port to be used for communication with the control
panel and start the firmware update.
5. Using the function available in the service mode, start the STARTER program in the
control panel (RESTARTS STARTER).
During operation of the STARTER program the control panel does not perform
its normal functions (only the status of electronic fuses being monitored).
The STARTER program is waiting 2 minutes for the procedure of control panel
firmware update to begin. If it does not happen, the control panel will return to
the service mode.
If the firmware update is suddenly terminated (e.g. due to loss of power) and, as
a result, the control panel firmware is damaged, the STARTER program will start
automatically and will remain active until the correct firmware is installed.
You can run the STARTER program by shorting the RESET pins when starting
the control panel – remove the short immediately after power-up (within approx.
one second).