54 Programming SATEL
80. ARMING violation of the zone will arm the partition to which the zone belongs.
Additionally, you can select a group of partitions which will also be armed (see: Groups of
partitions” p. 58).
81. DISARMING violation of the zone will disarm the partition to which the zone belongs.
Additionally, you can select a group of partitions which will also be disarmed (see: Groups
of partitions” p. 58).
82. ARM/DISARM the zone controls the arming status of the partition it belongs to.
The control mode depends on the CONTR. BY PULSE(OFF-BY STATE) option. Disarming may
simultaneously clear the alarm and cancel the messaging.
83. CLEARING ALARM violation of the zone will clear alarm in the selected group of partitions
(see: Groups of partitions p. 58) or the partition to which the zone belongs, and can also
cancel messaging.
84. GUARDviolation of the zone is recognized as recording the guard's round in the partition
to which the zone belongs.
85. ENTRY/EXIT CONDITIONAL similarly as the 0. ENTRY/EXIT type with an extra feature: the
zone becomes an instant one upon arming, if no partition exit is registered upon starting
the arming procedure.
86. ENTRY/EXIT FINALsimilarly as the 0. ENTRY/EXIT, but the zone restore during exit delay
countdown will terminate the exit delay countdown and arm the system.
87. EXIT FINAL similarly as the 6. EXIT, but the zone restore during exit delay countdown
will terminate the exit delay countdown and arm the system.
88. 24H BURGLARY a permanently armed zone. Its violation will cause the burglary alarm.
89. FINISHING EXIT DELAY zone violation will reduce the partition exit delay time. It is possible
to program a shorter exit delay time. If this value remains not programmed, the exit delay
will be reduced to 4 seconds from the zone violation. There will be no effect if the zone is
violated and the just running exit delay is shorter than that programmed for the zone.
90. DISABLING VERIFICATION zone violation will disable verification of alarms in the partition.
All alarms will be unverified until next arming.
91. DETECTOR MASK the permanently armed zone, dedicated to anti-masking control.
Violation of the zone will be treated by the control panel as detector trouble (masking).
92. OUTPUTS GROUP OFFthe zone allows to deactivate a selected group of outputs.
93. OUTPUTS GROUP ONthe zone allows to activate a selected group of outputs.
94. ENTRY/EXIT INTERIOR similarly as the 0. ENTRY/EXIT, but it will only be armed in the case
of full armed status (arming modes 0 and 1).
95. ENTRY INTERIOR similarly as the 1. ENTRY, but it will only be armed in the case of full
armed status (arming modes 0 and 1).
96. FIRE MONITORING permanently armed zone. After the zone is violated, fire alarm
information is saved to the control panel memory.
97. FIRE PANEL FAULT. MONIT. permanently armed zone. After the zone is violated, an event
is saved to the control panel memory.
4.3.6 Zone options
Power up delay when the option is enabled, the zone will be bypassed for 120 sec. after
power-up (which prevents triggering alarms e.g. when starting the alarm control panel).
Priority when this option is enabled, arming will be impossible, if the zone is violated (e.g.
windows have been left open, etc.).
Contr. by pulse(off-by state) option for 82. ARM/DISARM zone type. If it is enabled,
violation of the zone will arm/disarm the partition (depending on the current status of the