SATEL INTEGRA Plus 55
partition). If the option is disabled, zone violation will arm, and the zone restore will disarm
the partition.
CHIME in module with this option enabled, zone violation can be signaled in partition
keypads, code locks and readers expanders assigned to the same partition as the zone
(the option CHIME must be enabled in the expander).
No alarm sign. in keypadoption for 13. PANIC-SILENT zone type. If it is enabled, alarm from
this zone will not be signaled on keypads. Clearing this alarm by means of keypad will not
be possible.
Outputs signaling the silent panic alarm can be deactivated using the CLEAR LATCHED
OUTPUTS user function.
Video on disarmed if this option is enabled, violating the zone when the partition is
disarmed will activate the 15. VIDEO ON DISARMED type output.
Video on armedif this option is enabled, violating the zone when the partition is armed will
activate the 16. VIDEO ON ARMED type output.
Bypass disabledif this option is enabled, the user cannot bypass the zone.
Bypassed if no exit if this option is enabled, the zone will be automatically bypassed,
when no partition exit is registered during the partition exit delay countdown. The zone will
also be bypassed when the full + bypassesarming mode is on (registering a partition exit
is irrelevant then). The zone will be unbypassed after the partition is disarmed.
Alarm in arm state an option for the zone types 64-79. It is available, if the NO BYPASS IF
ARMED
option is enabled. When it is enabled, violating an armed zone will cause an alarm
(if the partition exit was registered upon arming).
Alarming option available for the 91. DETECTOR MASK zone type. If enabled, violation of the
zone will additionally trigger an alarm.
Auto-reset 3 with this option enabled, the zone can trigger up to 3 alarms. As long as the
alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not
trigger any alarm.
Auto-reset 1 with this option enabled, the zone can trigger only 1 alarm. As long as the
alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not
trigger any alarm.
Clearing Autoreset with this option enabled, alarm counters for the zones for which the
AUTO-RESET 3 or AUTO-RESET 1 option is enabled can be automatically reset at midnight
(violations of these zones will be able to trigger alarms again).
Pre-alarm if this option is enabled, alarms from the zone will be verified.
With verification an option for the zone types 0-2, 85-86 and 94-95. If it is enabled, alarms
from the zone will be verified.
Alarm from the zone with enabled PRE-ALARM or WITH VERIFICATION option will be an
unverified alarm, unless during verification (see description of the ALARM VERIFICATION
TIME parameter p. 46) an alarm will be caused by another zone with enabled PRE-
ALARM or WITH VERIFICATION option. In such a case, a verified alarm will be triggered.
Bell delay an option for the zone types 5 and 6. It changes the way of reaction to a zone
violation when armed. If the option is disabled, the alarm from zone will be delayed by
a programmed time period (ALARM DELAY). If the option is enabled, the zone will alarm
immediately (event, reporting and telephone messaging), but the loud signaling will be
delayed by a programmed time period (SIGNALING DELAY).
Delay in 2&3 type arming an option for the 3. INTERIOR DELAYED zone type. If the option is
enabled, the zone will be armed and act as a delayed one upon activation of the type 2
(without interior) and type 3 (without interior and without entry delay) arm mode.