74 Programming SATEL
AC loss report delay – time during which the control panel must not receive AC power so
that information of it can be saved to the event log. Having programmed the value 0
means that the information of AC power loss will not be saved to the event log.
Tel. line loss report delay – time during which abnormal voltage must be on the telephone
line for the control panel to report the telephone line trouble. A delay in reporting the
trouble prevents sending information about short-time voltage dips (e.g. during a phone
call) or decays.
Default part. block time – the time period during which the WITH TEMPORARY BLOCK type
partitions with enabled DEFAULT BLOCK TIME option will be blocked.
Summer/winter time [Daylight saving] – the control panel can automatically adjust the clock
settings due to a change from the summer time to the winter time according to the
selected schedule.
Summer time from – if the control panel clock is to be corrected by 1 or 2 hours according to
dates, you should enter the dates (day, month) after the clock is changed to the summer
time (moved forward).
Winter time from – if the control panel clock is to be corrected by 1 or 2 hours according to
dates, you should enter the dates (day, month) after the clock is changed to the winter
time (moved back).
RTC clock correction [Clock adjustm.] – if the accuracy of control panel clock is inadequate,
the clock settings may be adjusted once per 24 hours (at midnight) by a defined time. The
correction time is programmed in seconds. The maximum correction can be ±19 seconds
per 24 hours.
Time server – if the control panel is to synchronize the time with the server (automatically
and after suitable function is enabled by the installer or master user), enter the address of
time server supporting the NTP protocol. Time synchronization is possible when the
ETHM-1 / ETHM-1 Plus / INT-GSM module is connected.
Time zone – if the control panel is to synchronize the time with the server, indicate the time
zone, i.e. the difference between the universal time (GMT) and the zone time.
Do not report time server connection trouble [No t.serv.trbl] – with this option enabled, no
trouble will be reported if there is no communication with the time server.
6.6 Service options and parameters
In the keypad, most of the options and parameters, as described below, are available in SM
SETTINGS
submenu.
Service access code – a code that allows access to the service mode, as well as some
functions in the user menu.
Disable service mode [Block SM] – with this option enabled, entering the service mode
“from pins” (by hardware means) will be impossible (entering the service mode “from pins”
will only be possible if the control panel factory settings are restored).
Disable downloading [Block DWNL] – with this option enabled, starting communication with
the DLOADX program “from pins” will be impossible.
Hide service mode after [Hide SM after] – the time counted from the last operation
performed in the service menu, after expiry of which the service mode menu will be hidden
(see: p. 6). If value 0 is programmed, the automatic hiding of the service mode will be
disabled.
Service mode beep [SM sounds] – with this option enabled, the service mode will be
acoustically signaled in the keypad.