SATEL INTEGRA Plus 65
Timer activates/deactivates the option applies to the 24. MONO SWITCH and 25. BI SWITCH
outputs. If enabled, the output can be controlled by selected timers. Turning the timer ON
activates the output (in case of the 24. MONO SWITCH type output for a programmed
time), and turning the timer OFF deactivates the output.
ON/OFFthe option refers to the 24. MONO SWITCH type outputs. If it is enabled, violation of
the control zone when the output is on will turn the output off. If the option is disabled,
each violation of the control zone will turn the output on for a preset time.
Not controlled by arming the option refers to the 105. SHUTTER UP and 106. SHUTTER
DOWN
type outputs. If enabled, the partition arming / disarming has no effect on the output
status.
5.4 Output triggering
Zonesindicate the zones. The output will be controlled by events related to these zones.
LCD keypads indicate the LCD keypads. The output will be controlled by events related to
these LCD keypads.
Partitions indicate the partitions/partition keypads. The output will be controlled by events
related to these partitions/partition keypads.
Timers indicate the timers which will control the output.
Master users / users indicate the masters/users. The output will be controlled by events
related to these masters/users.
Outputs indicate the output. The output will be controlled by events related to these
outputs.
Expanders indicate the expanders. The output will be controlled by events related to these
expanders.
Troubles indicate the troubles. The output will be activated by occurrence of these
troubles.
Voice mess. indicate the synthesizers. The output will be active when the voice messages
with indicated numbers are played back.
Remote switches indicate the remote switches. The users will control the output by
controlling the selected switches via the telephone.
Burglary zones in partition indicate the partition in which the output will be activated by
starting the test of burglary zones.
Fire/technical zones in partition indicate the partition in which the output will be activated
by starting the test of fire or technical zones.
Arm modeindicate the arm mode whose activation will activate the output.
Telephone usage type indicate which cases of using the telephone communication by the
alarm control panel will activate the output.
5.5 Clearing alarm in partitions
Indicate the partitions in which alarm clearing will be available (the users having access to
these partitions will be able to clear the alarm).
The alarm must be signaled in the partition where it is to be cleared. If no alarm is
being signaled by the given partition, it will be impossible to clear it.
5.6 Output disabling
Disabling timers for the 105. SHUTTER UP and 106. SHUTTER DOWN type outputs, you can
indicate the timers which will block the output. When the timer is active, disarming
(105. SHUTTER UP) / arming (106. SHUTTER DOWN) will not activate the output.