82 Programming SATEL
In case of the authentication using code and card, the executed function depends on
the second identifier.
The outputs 255 and 256 cannot be used for controlling the authentication method.
8. Timers
The timers enable some functions to be automatically executed by the control panel
(arming/disarming, turning on/off devices connected to outputs, etc.). The timer compares the
time to that of the control panel clock and executes the selected function at the programmed
time.
8.1 Programming the timers
The timers can be programmed:
using the keypad, in the service mode, by means of the functions available in the TIMERS
submenu,
using the DLOADX program, in the Timerswindow.
8.2 Timer parameters
Name individual timer name (up to 16 characters).
User edits if this option is enabled, the users can edit the timer parameters by using the
keypad ([code] CHANGE OPTIONS TIMERS).
Parameters of the timers indicated as the controlling ones for the 120. THERMOSTAT
type output can be edited by the user even if the USER EDITS option is disabled (see:
120. Thermostat output parameters” p. 66).
[day of week]you can program the timer start/end time for each day of the week.
Everyday you can program the timer start/end time which will apply to those days of the
week for which no timer start/end time has been programmed.
Exception the period during which the timer will be started/ended at a different time. 4
exceptions can be programmed for a timer. You can program for each exception:
the date from which the exception will apply,
the date to which the exception will apply,
the timer start/end time when an exception applies.
If a year is programmed for an exception, the setting will only be valid for the current
year. If no year is programmed (the 9999 sequence is entered in the keypad instead of
the year), the exception will be valid every year.
Arming mode the arming mode which will be activated when the timer starts (in the
DLOADX program, enter an additional digit next to the timer start time: 0 full arming; 1
full arming + bypasses; 2 arming without interior; 3 arming without interior and without
entry delay).
9. User schedules
User schedules should be defined for the needs of the SCHEDULE type users (see: USER
MANUAL
). You can program the user schedules:
using the keypad, in the service mode, by means of the functions available in the USER
SCHEDULES
submenu,
using the DLOADX program, in the Timerswindow, User Schedulestab.