SATEL INTEGRA Plus 73
the ISOLATE user function is only available to the installer,
the SYSTEM STATE user function provides information about alarms, bypassed zones,
troubles and partition status (disarmed or type of armed mode).
Tamper if no communication with ABAX device (2h) [L.no ABAX=tamp] with this option
enabled, tamper alarm will be triggered if there is no communication with a wireless device
of the ABAX 2 / ABAX system for 2 hours.
No shortcuts in menu if this option is enabled, the user menu shortcuts are not supported.
Do not report SATEL server connection trouble [No SATEL trbl.] if this option is
enabled, loss of communication with the SATEL server will not be reported as trouble.
Do not report LAN loss on AC loss [No LAN(AC) tr.] if this option is enabled, trouble will
not be reported after Ethernet network loss in the event of control panel AC power failure.
6.4 Arming options
Display violated/bypassed zones on arming [Arm, view viol] if this option is enabled, the
user will be informed of the violated / bypassed zones when arming the system from
keypad.
If the system is being armed in the full + bypasses” mode, bypasses and violations of
the zones for which the BYPASSED IF NO EXIT option is enabled are not checked.
If the system is being armed in the without interioror without interior and without
entry delaymode, bypasses and violations of the 3. INTERIOR DELAYED type zones are
not checked (unless the DELAY IN 2&3 TYPE ARMING option is enabled for the zone).
Warn while arming if trouble [Arm, warn.trb.] if this option is enabled, the user will be
informed of the existing troubles, if any, when arming the system from keypad.
Do not arm if tampered [If tamper] if this option is enabled, arming will be impossible if
a tamper is discovered.
Do not arm if reporting trouble [If monit.trbl.] if this option is enabled, arming will be
impossible in case of any problems with reporting.
Do not arm if battery trouble [If batt. trbl.] if this option is enabled, arming will be
impossible in case of a battery failure.
Do not arm if outputs trouble [If outs. trbl.] if this option is enabled, arming will be
impossible when the control panel detects that the mainboard outputs are overloaded or
devices connected to these outputs are cut off.
Do not arm if trouble [If other trbl.] if this option is enabled, arming will be impossible in
case of a trouble.
Required system reset after verified alarm [If verif. al.] if this option is enabled, arming
will be impossible after a verified alarm.
The options DO NOT ARM IF TAMPERED, DO NOT ARM IF BATTERY TROUBLE, DO NOT ARM IF
TROUBLE, DO NOT ARM IF OUTPUTS TROUBLE and DO NOT ARM IF REPORTING TROUBLE are
available, when the WARN WHILE ARMING IF TROUBLE option is enabled.
6.5 Times
Global entry delay parameter taken into account in the delayed zones, for which the
programmed ENTRY DELAY is equal to 0.
Global alarm time time of signaling alarm in keypads, proximity card arm/disarm devices,
proximity card readers and DALLAS chip readers.
No armed indication after time counted from the moment of partition arming, during which
information about armed status is displayed on the keypads. Programming the value 0
means that keypads will indicate the armed status as long as the partition is armed.