72 Programming SATEL
the following global options are disabled (cannot be enabled):
DO NOT ARM IF TAMPERED,
DO NOT ARM IF BATTERY TROUBLE,
REQUIRED SYSTEM RESET AFTER VERIFIED ALARM,
DO NOT ARM IF TROUBLE,
DO NOT ARM IF OUTPUTS TROUBLE,
DO NOT ARM IF REPORTING TROUBLE,
the TAMPER ALARM ALWAYS LOUD option is disabled for all zones, keypad and expander
buses (the option cannot be enabled),
the VALID WITHIN 30 SEC option is enabled for all partitions (cannot be disabled),
the entry delay time (global and for individual zones) can be up to 45 seconds (if longer,
it will be automatically reduced) for the 0. ENTRY/EXIT, 1. ENTRY, 2. DELAYED, 3. INTERIOR
DELAYED
, 85. ENTRY/EXIT CONDITIONAL, 86. ENTRY/EXIT FINAL, 94. ENTRY/EXIT
INTERIOR
and 95. ENTRY INTERIOR zone types,
the REPORTING DELAY option is enabled for the 4. PERIMETER, 5. INSTANT, 6. EXIT,
7. DAY/NIGHT and 64...79 BYPASSING GROUP: 1...16 zone types (the option cannot be
disabled),
the ABORT DELAY option is enabled for the 0. ENTRY/EXIT, 1. ENTRY, 2. DELAYED,
3. INTERIOR DELAYED, 85. ENTRY/EXIT CONDITIONAL, 86. ENTRY/EXIT FINAL,
94. ENTRY/EXIT INTERIOR and 95. ENTRY INTERIOR zone types (the option cannot be
disabled),
the PRIORITY option is enabled for the 9. 24H TAMPER zone type (the option cannot be
disabled),
the AUTO-RESET 3 and AUTO-RESET 1 options are disabled for the 12. PANIC AUDIBLE and
13. PANIC SILENT zone types (the options cannot be enabled),
AC loss report delay (for the control panel and all modules with power supply units) can
be up to 60 minutes (if longer, it will be automatically reduced),
AC loss report delay (for the control panel and all modules with power supply units)
cannot be equal to 0 (if the value 0 is entered, 1 minute will be programmed),
the quick arming is not possible (relevant parameters in keypads settings are
automatically modified),
the SHOW ARM MESSAGES option is enabled in all keypads (it cannot be disabled),
the following options are disabled in all keypads (they cannot be enabled):
SIGNALING TROUBLES IN PARTIALLY ARM,
SIGNAL NEW TROUBLE,
ALARM MESSAGES: PARTITIONS,
ALARM MESSAGES: ZONES,
SHOW VIOLATED ZONES,
DISPLAY MODE SWITCHING,
it is not possible to view the status of zones, partitions, alarms, trouble memory and
current troubles by pressing and holding down the dedicated keypad keys (the
corresponding options are disabled and cannot be enabled),
it is not possible to present information on partition status in the bottom line of keypad
display (relevant parameters in the keypad settings will be automatically modified),
after entering the user menu by means of the service code, you will get access in the
EVENTS submenu to the GRADE 3 function, which enables viewing the events required by
EN 50131 for Grade 3,