SATEL INTEGRA Plus 71
of extended security alarm systems, where electric interference may cause problems with
communication.
No module restart reports [No rest. mon.] – when the option is enabled and the Contact ID
or SIA format is used for reporting, no event codes referring to module restarts will be sent
to the monitoring station.
Service message after tamper alarm [Inf.aft.tamper] – when the option is enabled, after any
tamper alarm, the keypads can display on LCD display the message informing that service
maintenance is necessary. The message will be cleared after entering the service code
and confirming it with the key.
Backlight off on AC loss [No AC-no blght] – when this option is enabled, the backlighting in
keypads can be automatically switched off in case of 230 V AC power loss.
Block keypad after 3 wrong codes [Blk aft.w.code] – with this option enabled, entering an
invalid code (reading in an invalid card / DALLAS iButton) three times will block the keypad
(reader) for 90 seconds. After expiry of that time, each next entry of an invalid code (read-
in of an invalid card / DALLAS iButton) will block the device immediately.
Trouble memory until review [Troubl. memory] – if the option is enabled, the trouble
memory can be signaled until it will be cleared (clearing the trouble memory is possible
when exiting the function of viewing troubles in the keypad or in the “Troubles” window,
DLOADX program).
Do not show alarm if armed [Hide alarms] – with this option enabled, no alarms will be
indicated in keypads during the armed mode.
Limit events [Events limit.] – with this option enabled, while armed events from the same
source will be saved into the event log and reported to the monitoring station 3 times only.
Alarming zones review [View clear.al.] – if this option is enabled, in the LCD keypad the
zones that triggered the alarm can be reviewed immediately after the alarm is cleared.
Grade 3 – with this option enabled, the system operates as required by the EN 50131
standard for Grade 3, i.e.:
– starting the arming procedure may be impossible, or, if started, the arming procedure
may fail, if some zones are violated in the partition, or there is a trouble in the system,
– LCD keypads, partition keypads, proximity card arm/disarm devices and reader
expanders do not signal alarms,
–
the
LEDs in keypads indicate alarms only when code has been entered and
confirmed with the key,
– the blinking LED in keypads means that there is a trouble in the system, some
zones are bypassed, or there has been an alarm,
– new access codes in the system must be composed of at least 6 characters (USER CODE
MIN
. LENGTH parameter),
– information on the arm status is displayed for maximum 60 seconds (NO ARMED
INDICATION AFTER
parameter),
– the following global options are enabled (cannot be disabled):
TROUBLE MEMORY UNTIL REVIEW,
DO NOT SHOW ALARM IF ARMED,
BLOCK KEYPAD AFTER 3 WRONG CODES,
WARN WHILE ARMING IF TROUBLE,
DISPLAY VIOLATED/BYPASSED ZONES ON ARMING,
DO NOT REPORT SATEL SERVER CONNECTION TROUBLE,
DO NOT REPORT SMTP SERVER CONNECTION TROUBLE,
DO NOT REPORT TIME SERVER CONNECTION TROUBLE,