J18 Event Column
Range: 0...127 Default: 8
J19 Set Line to Zero ED:>0
Range: 0...117 Default: 10
J20 Set Column to Zero ED:>0
Range: 0...127 Default: 8
J21 Line Number Nb
Range: 0...117 Default: 3
J22 Column Number Nb
Range: 0...127 Default: 8
Block K : Maintenance Int.
K01 Maintenance Elec.
Range: 0...10000 h Default: 3000 h
Message: S4 (K 02)
Alerts you on maintenance work to be effected after a
certain voltage ON-time.
K02 Event Maint. EL S4
Range: WARNING 1
WARNING 2
IGNORE
Default:
WARNING 1
The total of voltage ON-times exceeds the time
defined by K 01.
When the set interval has elapsed, message S4 is
output.
K03 Maint. STR-Meter
Range: 0...10000 h Default: 3000 h
Message: S3 (K 04)
Alerts you of maintenance work to be effected after a
certain conveyor belt run time.
K04 Event Maint. Run. S3
Range: WARNING 1
WARNING 2
IGNORE
Default: WARNING 1
The total of conveyor belt run times exceeds the time
defined by K 03.
When the set interval has elapsed, message S3 is
output.
K05 SPC Time
Range: 1...24 h Default: 8 h
Acquisition interval for service values, e.g. empty belt.
SPC = Statistical Process Control
0837
INTECONT PLUS VBW
Parameterization
BV-H2214 GB 65