J04 Reset Print FMZ 1
Range: NO
YES
Default: NO
YES : Reset counter 1 upon start of next batch
provided that batch report has been
printed. 1)
NO : Counter 1 can be reset only using the
control function.
1) also possible without printer (J 02, J 04= YES).
J05 Reset Print FMZ 2
Range: NO
YES
Default: NO
See J 04, however, for counter 2.
J06 Print Page Length
Range: 9...127 lines Default: 72 lines
The page must be minimum 4 times longer than the
number of data to be printed.
The line spacing is always 1/6 inch.
Change of parameter automatically initializes printer.
J07 Batch Setp. Line
Range: 0...117 Default: 6
J08 Batch Setp. Col.
Range: 0...127 Default: 8
J09 Batch Act. Line
Range: 0...117 Default: 7
J10 Batch Act. Col.
Range: 0...127 Default: 8
J11 FMZ 1 Line
Range: 0...117 Default: : 8
J12 FMZ 1 Column
Range: 0...127 Default: 8
J13 FMZ 2 Line
Range: 0...117 Default: 9
J14 FMZ 2 Column
Range: 0...127 Default: 8
J15 Date/Time Line
Range: 0...117 Default: 4
J16 Date/Time Col.
Range: 0...127 Default: 8
J17 Event Line
Range: 0...17 Default: 12
0837
VBW INTECONT PLUS
Parameterization
BV-H2214 GB 64
Technische
Redaktion PDE-RD
Transmission to third parties and reproduction of
this documentation are not permitted. Schenck
Process GmbH reserves all rights of ownership
and copyrights.