EasyManuals Logo

Schenck process Intecont Plus Belt Weigher User Manual

Schenck process Intecont Plus Belt Weigher
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
Block J : Printer Setting
J01 Baud rate
Range: 2400
4800
9600
19200
38400
Default: 9600
Baud rate for transmission to printer.
J02 Auto Print
Range: NO
YES
Default: NO
NO :
Batch report can be printed only using the
control menu.
YES : Batch report is printed automatically when
batch is complete.
J03 Print Subtotal
Range: Error
YES
NO
Default: Error
Error : Each event is printed automatically as soon
as available.
YES : See above, however, including totalizing
counter (FMZ) sub-totals.
NO : No printout
Printing is effected in batching and normal modes.
Save parameter J 03, all parameters are valid for batch
and counter reports.
Special case:
If a value is set to line 0 and column 0, it does not
appear in report.
0837
INTECONT PLUS VBW
Parameterization
BV-H2214 GB 63
Transmission to third parties and reproduction of
this documentation are not permitted.
SchenckProcess GmbH reserves all rights of
ownership and copyrights.
Technische
Redaktion PDE-RD
Print Batch
Batch number 12
30.06.03 11:45:10
Batch Setpoint 1000 kg
Batch Actual Val. 998 kg
Totalizer 1 1200 kg
Totalizer 2 90000 kg
Zero Set before 75 min
Events
30.09.97 11:45:21L2 W1 Load < MIN
0.09.97 11:59:01L2 W1 Load < MIN
Event report

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Intecont Plus Belt Weigher and is the answer not in the manual?

Schenck process Intecont Plus Belt Weigher Specifications

General IconGeneral
BrandSchenck process
ModelIntecont Plus Belt Weigher
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals