Block J : Printer Setting
J01 Baud rate
Range: 2400
4800
9600
19200
38400
Default: 9600
Baud rate for transmission to printer.
J02 Auto Print
Range: NO
YES
Default: NO
NO :
Batch report can be printed only using the
control menu.
YES : Batch report is printed automatically when
batch is complete.
J03 Print Subtotal
Range: Error
YES
NO
Default: Error
Error : Each event is printed automatically as soon
as available.
YES : See above, however, including totalizing
counter (FMZ) sub-totals.
NO : No printout
Printing is effected in batching and normal modes.
Save parameter J 03, all parameters are valid for batch
and counter reports.
Special case:
If a value is set to line 0 and column 0, it does not
appear in report.
0837
INTECONT PLUS VBW
Parameterization
BV-H2214 GB 63
Transmission to third parties and reproduction of
this documentation are not permitted.
SchenckProcess GmbH reserves all rights of
ownership and copyrights.
Technische
Redaktion PDE-RD
Print Batch
Batch number 12
30.06.03 11:45:10
Batch Setpoint 1000 kg
Batch Actual Val. 998 kg
Totalizer 1 1200 kg
Totalizer 2 90000 kg
Zero Set before 75 min
Events
30.09.97 11:45:21L2 W1 Load < MIN
0.09.97 11:59:01L2 W1 Load < MIN
Event report