L04 Word sequence
Range: I: std/L:std
I: swp/L: std
I: std/L: swp
I: swp/L: swp
Default: I: std/L: std
The parameter determines the word sequence within
a double word.
“I” stands for IEEE-754 values (floating point values)
“L” stands for 4-Byte integer values
“std” does not reverse the word order, “swp” swaps
them.
L05 Byte sequence
Range: LOW-High
High-LOW
Default: LOW-High
Determines the byte sequence in a data word.
L06 Configuration
Range: FIXED
NO-PARA-ID
PARA-ID
PARA-6ID*
Default: FIXED
Determines the structure and the size of the process
image.
Only with fieldbus card VxB8020.
L07 Address
Range: 1...254 Default: 1
Slave address for Modbus protocol.
L08 Resolution
Range: 1...32767 Default: 4096
Resolving the data in the Modbus protocol nominal
value (integer format).
L09 Physical attributes
Range: RS485
RS422
RS232
Default: RS 485
Modbus baud rate.
L10 Baud Rate
Range: 2400
4800
9600
19200
38400
Default: 9600
Modbus-Baudrate.
L11 Data format
Range: 8-E-1
8-0-1
8-N-2
8-N-1
Default: 8-E-1
Modbus data format (data bits-parity-stop bits).
L12 Address
Range: 0...126 Default: 16
Profibus DP Slaveadresse
L13 FLOAT-FORMAT
Range: SIEMENS-KG
IEEE
Default: IEEE
Determines the display of the floating point value for
the Profibus DP protocol.
0837
VBW INTECONT PLUS
Parameterization
BV-H2214 GB 68