Block M : Feeder Control
M01 Feeder Active
Range: YES
NO Default: NO
YES : The START/STOP Prefeeder dialog function
is active. In turned-on state, the prefeeder is
controlled through the scale-specific
sequence.
NO : Dialog function is faded out.
Control output is always set to STOP
Prefeeder.
M02 Setting Time
Range: 0.0...1000.0 s Default: 0.0 s
Setting time of material prefeeder
M03 Feed Distance
Range: 0.00...10000.00 m Default: 0.00 m
Material path from prefeeder to end of weighbridge.
Input is required only if Full Feed / Dribble Feed
control via prefeeder is desired.
M04 Motor STOP aft. ST
Range: NO
YES Default: NO
NO : After cut-off or batch complete command,
belt continues running for the time specified
by Parameter M02.
YES : Conveyor belt immediately stops.
Parameter is active only if Batch Mode has been
preselected.
Normally, belt immediately stops.
M05 Change-over FF/DF
Range: YES
NO Default: YES
I 07 = YES Belt clearance.
M 05 ineffective.
I 07 = NO No belt clearance.
Parameter M 05 lets you select Full
Feed / Dribble Feed control via
conveyor belt (NO), or prefeeder
(YES).
0837
VBW INTECONT PLUS
Parameterization
BV-H2214 GB 70
Technische
Redaktion PDE-RD
Transmission to third parties and reproduction of
this documentation are not permitted. Schenck
Process GmbH reserves all rights of ownership
and copyrights.