113
www.sauservice.com
FIG. 13 b
CRADLE
13. COIN SELECTOR
The coin selector should be cleaned once every 3 months.
When cleaning, follow the procedure below:
● Turn the power for the machine OFF. Open the coin chute
door.
● Open the gate and dust off by using a soft brush (made of
wool, etc.).
● Remove and clean smears by using a soft cloth dipped in
water or diluted chemical detergent and then squeezed dry.
● Remove the CRADLE.
When removing the retaining ring
(E ring), be very careful so as not to bend the rotary shaft.
● Remove stain from the rotary shaft and shaft receiving por-
tions by wiping off with a soft cloth, etc.
● After wiping off as above, further apply a dry cloth, etc. to
cause the coin selector to dry completely.
CLEANING THE COIN SELECTOR
COIN INSERTION TEST
Once every month, when performing the Coin SW
Test, simultaneously check the following:
● Does the Coin Meter count satisfactorily?
● Does the coin drop into the Cashbox correctly?
● Is the coin rejected when inserted while keeping the
Reject Button pressed down?
● Remove and clean smears by using a soft cloth
dipped in water or diluted chemical detergent and
then squeezed dry.
● Never apply machine oil, etc. to the Coin Selec-
tor.
● After cleaning the Coin Selector, insert a regular
coin in the normal working status and ensure that
the Selector correctly functions.
FIG. 13 a
FIG. 13 c
GATE
Insert a coin
while keeping the
Reject Button
pressed down and
check if it is
rejected. t
COIN METER
If the coin is not rejected when the REJECT button is pressed, open the coin chute door and open the
selector gate. After removing the jammed coin, put a normal coin in and check to see that the selector
correctly functions.
HANDLING THE COIN JAM
STOP
IMPORTANT!