41
www.sauservice.com
When the game machines of a same or similar type are installed side by side, their sensors may interfere
with each other. To reject the interference, follow the procedure below.
The following game machines employ a same or similar type of sensor. If interference happens to the
sensors, operation of the games may be mutually disturbed.
THE HOUSE OF THE DEAD 2, U/R type, DX type and Super DX type
DEATH CRIMSON, U/R type and DX type
THE LOST WORLD, U/R type, DX type and Super DX type
BRAVE FIRE FIGHTERS
SAMBA DE AMIGO
CONFIDENTIAL MISSION, U/R type and DX type
SHAKATTO TAMBOURINE
LUPIN THE 3
RD
THE SHOOTING, U/R type and DX type
THE MAZE OF THE KINGS, U/R type and DX type
THE HOUSE OF THE DEAD 3, U/R type and DX type
VIRTUA COP 3, U/R type and DX type
GHOST SQUAD, U/R type and DX type
PHOTO 6. 9 a
In order to prevent electric shock and short circuit hazards, be sure to turn power off
before performing work.
Be careful not to damage the wires. Damaged wires may cause electric shock or
short circuit or present a fire risk.
Do not expose the IC BD, etc. without a good reason. Failure to observe this can
cause electric shock hazard or malfunctioning.
Work should be performed by the Location's Maintenance Man or technical person-
nel. Performing work by those who do not have technical knowledge and expertise
can cause electric shock accident or malfunctioning.
Interference Prevention Wiring
Turn the power off.
Undo the 2 truss screws and remove the side door
L from the main cabinet.
TRUSS SCREW (2), black T
M4×40, flat washer used
SIDE DOOR L
WARNING!