PID checks:
Enable or disable alarming of PID presence errors, scrambling/clear
requirements and PID type checks. The checks are set in the PID
threshold template.
Service minimum
bitrate checks:
Enable or disable alarming of service minimum bitrate errors. Require-
ments are specified in the service threshold template associated with
the stream.
Service maximum
bitrate checks:
Enable or disable alarming of service maximum bitrate errors. Require-
ments are specified in the service threshold template associated with
the stream.
Service checks:
Enable or disable alarming of service presence, scrambling/clear re-
quired, service type, service name and service ID errors. Requirements
are specified in the service threshold template associated with the
stream.
Service checks –
Only allow services listed
in service template:
Check this box to enable service ID checks against the service ID list
specified in the service threshold template associated with the stream.
MIP checks:
Enable or disable alarming of errors related to the Megaframe Insertion
Packet.
MIP checks –
Require presence of MIP:
Check this box to enable an alarm if the MIP table is missing for the
stream.
MIP checks –
Max MIP timing
error(µs):
The maximum MIP timing error before raising an alarm. The unit is
µ
s.
Default: 10 µs
Content check
(Content Extraction and Alarming Option) Enable or disable alarming of
freeze-frame and color-freeze errors. Requirements are specified in the
service threshold template associated with the stream.
Gold TS check:
Enable or disable alarming for tables failing Gold TS reference checking.
Gold TS check –
Also check version
number and CRC:
When enabled an alarm will be raised for any change, including a
change in the table version number and CRC.
Gold TS check –
Verify PAT table:
Do verification of the PAT table against the stored reference PAT table.
Gold TS check –
Verify PMT tables:
Do verification of the PMT tables against the stored reference PMT
tables.
Gold TS check –
Verify CAT table:
Do verification of the CAT table against the stored reference CAT table.
VB2xx GigE User’s Manual version 5.4 161