Gold TS check
Verify SDT actual table:
Do verification of the SDT actual table against the stored reference SDT
actual table.
Gold TS check
Verify SDT other tables:
Do verification of the SDT other tables against the stored reference SDT
other tables.
Gold TS check
Verify BAT table:
Do verification of the BAT table against the stored reference BAT table.
Gold TS check
Verify NIT actual table:
Do verification of the NIT actual table against the stored reference NIT
actual table.
Gold TS check
Verify NIT other tables:
Do verification of the NIT other tables against the stored reference NIT
other tables.
Time information check:
Enable or disable alarming if there are errors in the time information sent
in the streams. Probe should use NTP time sync to use this functionality.
Time information check
Check TDT:
Check the time in the TDT table and alarm if it is wrong.
Time information check
Check TOT:
Check the time in the TOT table and alarm if it is wrong.
Time information check
Check LTC:
Check the time in the Logical Time Code table and alarm if it is wrong.
Time information check
Max time offset:
The maximum number of seconds the time information provided in the
stream can deviate from the probe time before an alarm is raised.
Time information check
Max repetition time:
The maximum time without any time information before an alarm is
raised.
ETR Thresholds Interface checks:
Pre FEC bit error rate check:
If enabled an alarm will be raised provided that the pre FEC BER
measured is above the threshold value associated with the stream.
Only relevant for RF signals.
Post FEC bit error rate check:
If enabled an alarm will be raised provided that the post FEC BER
measured is above the threshold value associated with the stream.
Only relevant for RF signals.
Modulation error ratio check:
If enabled an alarm will be raised provided that the MER measured
is above the threshold value associated with the stream. Only
relevant for RF signals.
162 VB2xx GigE User’s Manual version 5.4