DMR transceiver
96
The NXDNReflector connector is an NXDN® connector, but it supports DMR and
C4FM cross modes, and D-STAR® with the openSPOT4 Pro.
Using a DMR transceiver
You can switch NXDNReflector servers with your DMR transceiver by calling the
desired server's ID with a private call.
Using a D-STAR® transceiver (openSPOT4 Pro only)
You can switch NXDNReflector servers with your D-STAR® transceiver by
entering DTMF code * followed by the desired server's ID (5 digits).
You can also use the URCALL/your call method. This lets you change to the
following server types:
REF/XRX/Gateway: set the URCALL to for example REF001 C . Switching to
REF/XRF servers or gateways this way changes the openSPOT4's active
connector to the REF/XRF connector.
DCS/XLX: set the URCALL to for example DCS001 A . Switching to DCS/XLX
servers this way changes the openSPOT4's active connector to the DCS/XLX
connector.
BrandMeister: set the URCALL to BM followed by the BrandMeister server
ID. Example: starting a call to destination callsign (URCALL) BM2162
switches to BrandMeister server 2162 (Hungary). Switching to BrandMeister
servers this way changes the openSPOT4's active connector to the
Homebrew/MMDVM connector.
FCS: set the URCALL to the FCS server and room number. Example:
starting a call to destination callsign (URCALL) FCS00199 switches to
FCS001 room 99. Switching to FCS servers this way changes the
openSPOT4's active connector to the FCS connector.
YSFReflector: set the URCALL to YS followed by the YSFReflector server
ID. Example: starting a call to destination callsign (URCALL) YS89804
switches to YSFReflector 89804 (AmericaLink). Switching to YSFReflector
servers this way changes the openSPOT4's active connector to the
YSFReflector connector.
NXDNReflector: set the URCALL to NX followed by the NXDNReflector
server ID. Example: starting a call to destination callsign (URCALL) NX28299
switches to NXDNReflector 28299 (America-Ragchew). Switching to
NXDNReflector servers this way changes the openSPOT4's active connector
to the NXDNReflector connector.
Using a C4FM transceiver
You can switch NXDNReflector servers with your C4FM transceiver by entering
the Special command/cross mode private call DTMF code DTMF code (by default
it's *) followed by the desired server's ID (5 digits).
You can also use the Wires-X® button menu of your C4FM radio to
select/search for servers.