* Item: Selection: Entry:
A Delete method (for only UPC) Delete in non-accessed UPC 0
For PLU, always enter 1.
deleting job (#105 in Z1 mode)
Inhibit to delete in non-accessed 1
UPC deleting job (#105 in Z1 mode)
B Condiment type PLU (for only PLU) Disable 0
For UPC, always enter 0. Enable 1
C Condiment entry (for only PLU) Allowed 0
For UPC, always enter 0. Compulsory 1
D Price shift entry Enable 0
Inhibit 1
Compulsory 2
E Tare table number 0 thru 9 (0: Not used)
F Scale entry Inhibit 0
Enable 1
Compulsory 2
G Type of unit price entry Prohibit mode 0
Open price only (for only PLU) 1
Preset price only 2
Open price and preset price (for only PLU) 3
Delete mode 4
To program ABCDEFG=1000003 for PLU1
For each PLU/UPC
To program ABCDEFG=1000003 for PLU11 thru 20
For a range
of PLUs
2231
.@
11
@
20
@
1000003
t
Ç
PrintKey operation
A thru G
2210
.@
1
@
1000003
t
Ç
PrintKey operation
Example