Programming Non-PLU code format
The register allows you to specify the Non-PLU code format (flag code: 2, 02, 20 -29).
The format data is as follows:
*
1
Flag code: 2, 02, 20 - 29
*
2
Item: Selection: Entry:
A Length of field 1 (number of digits) 0 - 9
B Length of field 2 (number of digits) 0 - 9
C Always enter 0. (Fixed position) 0
D Meaning of field 2*
3
Quantity 2
Price 0
E Price check digit used Yes 1
No 0
F TAB or decimal point of field 2 (0, 1, 2, 3) 0 - 3
*
3
: When you preset a quantity, the sales amount is calculated as follows: quantity x unit price programmed in
#1210.
ABCDEF
Flag code
2025
. `
20
`
540012
ı
c
PrintKey operation
C
D
PLU no.Flag
code
Price
P
D
20
Price check digit (TAB2)
Example
ı``
c
.
Flag code
(max. 2 digits)
2025
To delete
ABCDEF
*
2
*
1
Procedure
C
D
Free formatFlag
(02 or 20-29)
Field 2Field 1
Free format area
Price check digit