8 Operation
The track and trace system may only be operated by qualified persons.
Qualified persons have the specialist training, skills, experience and knowledge of the rele-
vant regulations and standards needed to be able to perform work assigned to them and
to identify and avoid any potential dangers independently.
8.1 System Start
▸ Set up the voltage supply for the cabinet.
▸ Connects the voltage supply for the MSC800 system controller and the connected sen-
sors.
▸ The sensors and controller are started up and checked for operational readiness in
a self-test.
The track and trace system is ready for use.
8.2 Check operational readiness
8.2.1 CLV691 Bar Code Scanner
Fig. 26: Operational readiness of the CLV691
● The Ready LED lights up.
8.2.2 CLV651 Bar Code Scanner
Fig. 27: Operational readiness of the CLV651
● The Ready LED lights up
Note
The white status LED on the cabinet lights up as soon as voltage is applied.
see chapter 8.2.5 MSC800 System Controller /page 50 and
chapter 8.2.6 System Readiness /page 50
Note
The conveying system must be started by customer.