Operating instructions Chapter 3
Flexi Classic
8011509/YPP0/2015-10-26 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 35
Subject to change without notice
Product description
3.5 UE410-XU module
The UE410-XU module is an input/output extension or a subsystem with 4 safe inputs and
outputs. It has the identical functionality to the UE410-MU main module, however without
the system save using the ENTER button.
The UE410-XU cannot be used as a stand-alone device and always requires a UE410-MU
main module.
3.5.1 Controls and status indicators
Indicators, controls and terminal assignments are the same as on the UE410-MU main
module (see Tab. 9-Tab. 11).
Fig.
11
:
UE410
-
XU controls
and status indicators
Program switch
Switch for off delay
(not on UE410-xxxT0)