Chapter 3 Operating instructions
Flexi Classic
18 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8011509/YPP0/2015-10-26
Subject to change without notice
Product description
3.2.3 UE410-8DI input extension module
The UE410-8DI module is an input extension with 8 inputs that can be linked using the OR,
AND or Bypass logic function to the respectively upstream UE410-MU, UE410-GU or
UE410-XU module. The 9 switch positions of the UE410-8DI rotary switch determine which
safety components can be connected to the UE410-MU/GU/XU and which type of logic is
used. The input extension module UE410-8DI acts exclusively on the next UE410-MU,
UE410-GU or UE410-XU module positioned to the left in the module structure, thus form-
ing a function group. It is allowed to connect a maximum of 8 UE410-8DI modules to a
UE410-MU, UE410-GU or UE410-XU.
For more informationen on this topic see section 4.12 “Grouping of subsystems” on
page 78.
3.2.4 UE410-XU input/output extension
The UE410-XU module is an input/output extension with 4 safety inputs, 4 semiconductor
outputs and 2 test outputs. It has the same switch positions, logic functions and facilities
for connecting sensors as the UE410-MU. In contrast to the UE410-MU and UE410-GU, the
UE410-XU cannot store the system configuration.
A UE410-XU can only be operated in combination with a UE410-MU or UE410-GU main
module.
A main module and a UE410-XU can be linked logically with each other, thus forming a
subsystem (for further information please refer to section 4.12 “Grouping of subsys-
tems” on page 78).
3.2.5 UE410-2RO/UE410-4RO output modules
The UE410-2RO/UE410-4RO output extensions make one or two dual-channel, contact-
based outputs available. They do not have any influence on the specified logic instructions
of a system structure and are controlled by the UE410-MU, UE410-GU or UE410-XU out-
puts.
3.2.6 Gateways
Gateways (fieldbus modules) can be added to the Flexi Classic modular system for diag-
nostic purposes. They output the system configuration and the input/output states as well
as the error and status information of all the modules.
Several gateways are available, e.g.:
UE410-PRO for PROFIBUS-DP
UE410-DEV for DeviceNet
UE410-EN1 for EtherNet/IP
The UE410-GU does not support all data sets from all gateways.
You will find a complete list of all gateways and the data sets supported in the operating
instructions “Flexi Classic Gateways” or in the Internet on our homepage www.sens-
control.com.
All gateways have 4 non-safe application diagnostic outputs. The outputs are short-circuit
protected (see also the Flexi Classic Gateways operating instructions).
Notes
Note

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Flexi Classic series and is the answer not in the manual?

SICK Flexi Classic series Specifications

General IconGeneral
BrandSICK
ModelFlexi Classic series
CategoryController
LanguageEnglish

Related product manuals