Closed-loop thyristor current control
System- and communication configuring D7-SYS - SIMADYN D 5-57
Edition 06.2002
parameter PA6.XDA.
e.g. PA6.XDA= 0.0 [°] PA6.AVW = -30 [°]
PA6.XDA= +10.0 [°] PA6.AVW = -20 [°]
Value range PA6.XDA {-180 [°] +180 [°] }.
Firing pulse
V
L1-MP
Pulse position change
with PA6.XDA:
+
...0...
-
V1
V2
α
= 150°
Ground at pin ITDC -X5:14
15V
7.5V
V5 V6V4V3
0V
Fig. 5-30 Pulse position for a correctly set offset angle
The correct firing pulse position must be checked after each
correction and if required should be further changed. The position
must be precise!
Switch-off command (SOL.ION = 0) or (SOL.ON1 = 0)
Switch-off the power to the Sitor set
Remove the measuring cables for phase voltage L1 (!) and pulses.
5.3.6 Determining the armature time constant TA
The armature time constant TA is determined, in the open-loop controlled
test mode using a “Current step” outside the discontinuous range.
The current actual value of the armature circuit should be plotted.
The SITOR set provides the current as voltage signal (I
rated
= -10V) at test
socket I
act
( –A1: bottom right, M right-4
th
socket from the bottom) or at
terminal–X15 :1 ( :3 is ground).
The current can be connected to an oscilloscope channel using a clip-on
ammeter or the internal value via the configured analog output.
The armature circuit should be closed again.
The motor rotor should be mechanically locked, as the remanence
field still generates a torque in the motor.
Open the field circuit and inhibit the excitation! (FCS.IE=0).
Pulse position for a
correctly set offset
angle
Procedure