5
5.6 Net data (PKW and PZD area)
5-257
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 5-25 Parameters for configuring the process data, continued
No. EffectiveUnitsMax.StandardMin.Name
Note:
For P0922 > 0, the following is valid:
P0915:17 is pre–assigned at run–up corresponding to the selected standard telegram in
P0922.
A change made to P0915:2 to P0915:16 is overwritten again at the next run–up corre-
sponding to the selected standard telegram.
Operating mode not specified ––> possible in every operating mode
The following applies for P0922 = 0:
Before SW 4.1 ––> From P0915:5 (assignment for PZD5), process data can be freely con-
figured. This means from P0915:5, the signal ID of the requested signal can be entered.
From SW 4.1 ––> From P0915:2 (assignment for PZD2), process data can be freely con-
figured, i.e. from P0915:2, the signal ID of the required signal can be entered.
P0915:0 No significance
P0915:1 PZD1 Configuring not possible (standard setting)
P0915:2 PZD2 Free configuring possible (from SW 4.1, before SW 4.1
from PZD5), i.e. enter the required signal ID
... ...
P0915:16 PZD16 Free configuring possible,
i.e. enter the required signal ID
An overview of the control words is available in Chapter 5.6.1.
The process data for encoder 2 must be activated via P0879.12.
5 Communications via PROFIBUS DP