A.1 Parameter list
A-735
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0026 Position actual value, external block change (–> 3.1)
Min Standard Max Unit Data type Effective
MSR Integer32 RO
... displays, in the ”Positioning” mode, the position actual value displayed when an edge is de-
tected at the ”External block change” input signal.
Note:
The parameter is reset when starting a traversing block with the block change enable CON-
TINUE EXTERNAL.
refer to the index entry ”block step enable – CONTINUE EXTERNAL”
0029 Following error
Min Standard Max Unit Data type Effective
MSR Integer32 RO
... in the ”positioning” mode and for the ”Spindle positioning” function, displays the actual follow-
ing error.
The following error is the difference between the position setpoint (before the position setpoint
filter, interpolator output) and the position actual value.
Note: refer to the index entry ”Kv factor” or ”Analog signals for the position control loop”
0030 Control deviation, position controller input
Min Standard Max Unit Data type Effective
MSR Integer32 RO
... in the ”positioning” mode and for the ”Spindle positioning” function, displays the actual
system deviation (reference value – actual difference) at the position controller input.
Note: refer to the index entry ”Kv factor” or ”Analog signals for the position control loop”
0031 Actual Kv factor (position loop gain)
Min Standard Max Unit Data type Effective
1000/min Floating Point RO
... in the ”positioning” mode and for the ”Spindle positioning” function, displays the actually avail-
able (measured) Kv factor.
Example:
A kv factor = 1 has been set in P0200:8.
When traversing the axis, the current (measured) Kv factor is calculated and displayed in this
parameter.
Note:
The actual Kv factor display (P0031) can have large values at low velocities due to the round-
ing-off errors.
At standstill, the selected (required) Kv factor (P0200:8) is displayed.
0032 Position reference value, external (–> 3.3)
Min Standard Max Unit Data type Effective
MSR Integer32 RO
... displays the externally entered position reference value.
Note:
The quantities of P0895 to P0897 are incorporated in P0032.
refer under the index entry ”axis couplings”
A Lists
01.99
! 611ue diff !
04.05