A
A.1 Parameter list
A-744
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0124 Teach-in configuration (–> 4.1)
Min Standard Max Unit Data type Effective
0 0 3 Hex Unsigned16 immed.
... specifies in which mode teach in is executed.
Bit 0 Automatic block change enable
In this mode, after each successful ”teach-in”, the teach-in block in P0120 is automatically in-
creased.
Bit 0 = 1 On
Bit 0 = 0 Off
Bit 1 Automatic block search
In this mode at ”teach-in” a search is made for the block in P0120.
Bit 1 = 1 On
The block, entered in P0120 or the block selected via the input signals, is re-generated.
Bit 1 = 0 Off
A fault is initiated if the block in P0120 or the block selected via the input signals is not avail-
able.
Note:
refer under the index entry ”Teach-in”
0125 Spindle positioning active (–> 5.1)
Min Standard Max Unit Data type Effective
0 0 2 – Unsigned16 PO
... switches the ”spindle positioning” function into the mode ”n-set” on/off.
0 De-activate spindle positioning
1 Activate spindle positioning
Note:
refer under the index entry ”Spindle positioning”
0126 Spindle positioning, zero mark tol. window (BERO) (–> 5.1)
Min Standard Max Unit Data type Effective
0 7200 360000 MSR Unsigned32 immed.
... specifies the zero tolerance window in degrees, which is monitored by the spindle position-
ing, in order to secure, in conjunction with a BERO, the zero mark consistency. If the zero mark
is not recognized, or if uneven zero mark clearances are measured which are outside the toler-
ance, then alarm message 186 or 193 is output, e.g. if the encoder cable is, for example, inter-
rupted.
0 De-activate zero mark monitoring
>0 Zero mark monitoring is activated
Note:
refer under the index entry ”Spindle positioning”
0127 Spindle positioning, setting the internal zero mark (–> 5.1)
Min Standard Max Unit Data type Effective
0 0 1 – Integer16 immed.
By setting bit 0 to 1, the zero mark offset to the hardware zero mark is entered into P0128. After
this, 0 is written back into P0127.
Note:
refer under the index entry ”Spindle positioning”