A
A.1 Parameter list
A-755
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0599 Active motor data set (–> 2.4)
Min Standard Max Unit Data type Effective
Unsigned16 RO
... displays whether the motor changeover has been enabled, and which motor data set is active.
0 Motor changeover inhibited (P1013 = 0)
1 Motor data set 1 (P1xxx) active
2 Motor data set 2 (P2xxx) active
3 Motor data set 3 (P3xxx) active
4 Motor data set 4 (P4xxx) active
Note: refer to the index entry ”Motor changeover”
0600 Operating display
Min Standard Max Unit Data type Effective
Hex Unsigned32 RO
... displays the actual operating status of the unit.
Note:
refer to the index entry ”Operating display” for the significance of the segments on the display
unit.
0601 Motor speed setpoint (ARM SRM)
Velocity setpoint, motor (SLM)
Min Standard Max Unit Data type Effective
m/min Floating Point RO (SLM)
rpm Floating Point RO (SRM ARM)
... is used to display the unfiltered summed setpoint for speed or velocity of the motor.
0602 Actual motor speed (ARM SRM)
Velocity actual value, motor (SLM)
Min Standard Max Unit Data type Effective
m/min Floating Point RO (SLM)
rpm Floating Point RO (SRM ARM)
... is used to display the unfiltered actual value for speed or velocity of the motor.
0603 Motor temperature
Min Standard Max Unit Data type Effective
–––C Integer16 RO
... displays the motor temperature measured via the temperature sensor.
Note:
The display is invalid if a fixed temperature was entered in P1608.
0604 Utilization, motor
Min Standard Max Unit Data type Effective
% Floating Point RO
This parameter is used to display the motor utilization.
The ratio between the ”Torque setpoint M” and ”Actual torque limit Mmax” or
”Force setpoint F” and ”Actual force limit Fmax” is displayed.
Values of less than 100% indicate the system reserve.
Note:
The motor utilization display is smoothed using a PT1 filter (P1251).
0606 Voltage at term. 56.x/14.x
Min Standard Max Unit Data type Effective
V(pk) Floating Point RO
... displays the analog voltage presently available at this input terminal.
A Lists
01.99
! 611ue diff !
04.05