A
A.1 Parameter list
A-850
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1782:17 Target offset PROFIBUS process data (–> 4.1)
Min Standard Max Unit Data type Effective
– – – Hex Unsigned16 RO
... indicates which offset the process data have in the telegrams sent to the master or the sub-
scribers via the PROFIBUS
(Counting in bytes, starting with 1).
The following is valid:
P1782:0 Number of valid entries
P1782:1 Target offset, process data 1 (ZSW1)
P1782:2 Target offset, process data 2 (PZD2), etc.
Note: refer to the index entry ”Process data”
1783:97 PROFIBUS parameterization data received (–> 3.1)
Min Standard Max Unit Data type Effective
– – – Hex Unsigned16 RO
... is an image of the parameterizing data received by the DP slave.
The sub-parameter
with index 0 contains the number of valid bytes of the parameterization frame
= 0 ––> no parameterizing data available
with index 1, the 1st byte includes the parameterizing data
with index 2, the 2nd byte includes the parameterizing data, etc.
1784:97 PROFIBUS configuration data received (–> 3.1)
Min Standard Max Unit Data type Effective
– – – Hex Unsigned16 RO
... is an image of the configuration data received by the DP slave.
The sub-parameter
with index 0 contains the number of valid bytes of the configuration frame
= 0 ––> no configuration data available
with index 1, the 1st byte includes the configuration data
with index 2, the 2nd byte includes the configuration data, etc.
1785:13 Expanded PROFIBUS diagnostics (–> 3.1)
Min Standard Max Unit Data type Effective
– – – – Unsigned16 RO
... contains diagnostic information for PROFIBUS operation. For the individual indices of P1785,
the following applies:
:0 Error, master sign-of-life since POWER ON
:1 Clock cycle-synchronous operation selected
:2 Interpolation clock cycle (Tipo) in µs
:3 Position controller clock cycle (Tlr) in µs
:4 Master application cycle time (Tmapc) in µs
:5 DP cycle time (Tdp) in µs
:6 Data Exchange time (Tdx) in µs
:7 Instant of the setpoint sensing (To) in µs
:8 Instant of the actual value sensing (Ti) in µs
:9 PLL window (Tpllw) in 1/12 µs
:10 PLL delay time (Tplld) in 1/12 µs
:11 External slave-to-slave communication links
:12 Internal slave-to-slave communication links
04.05